2024-05-24 17:00:18 评论: 点击:
What are the standard requirements for polyurethane directly buried finished insulation pipes? Firstly, the insulation layer thickness of the polyurethane directly buried finished insulation pipe should ensure that the outer protective pipe can be used normally within the temperature range of -50 ℃ to+50 ℃. Both ends of the steel pipe should be left with an exposed non insulated area of 150mm to 250mm for welding. Secondly, before and after foaming the polyurethane directly buried finished insulation pipe, the increase rate of the outer diameter of the same section at any position of the o
聚氨酯直埋成品保温管的标准要求有哪些?
首先聚氨酯直埋成品保温管的保温层厚度应保证外护管在-50℃~+50℃温度范围内正常使用。 钢管两端头应留出150mm~250mm裸露的非保温区以备焊接。 其次,聚氨酯直埋成品保温管发泡前后,外护管任一位置同一截面的外径增大率不应大于2%。 保温管任一位置外护管轴线与钢管轴线间的距离应符合表4(略)规定。 正常使用的聚氨酯直埋成品保温管寿命,在120℃下连续工作至少30年。 聚氨酯直埋成品保温管轴向剪切强度及试验方法应符合表5(略)规定。 最后,聚氨酯直埋成品保温管的抗冲击性按5.4.3测试时,外护管不应有可见裂纹。 在聚氨酯直埋成品保温管设置的报警线与报警线、报警线与钢管之间的电阻值为20MΩ~∞。
详情可参见聚氨酯保温管的国家标准《GBT29047-2021高密度聚乙烯外护管硬质聚氨酯泡沫塑料预制直埋保温管及管件》中的具体描述。